Cisco UCS C225 M6 SFF Rack Server

& Free Shipping

The Cisco UCS C225 M6 SFF Rack Server extends the capabilities of the Cisco Unified Computing System portfolio in a 1-Rack-Unit (RU) form factor with the addition of AMD CPUs as well as 16 DIMM slots per CPU for 3200-MHz DDR4 DIMMs with individual DIMM capacity points up to 256 GB. The maximum memory capacity for two CPUs is 8 TB (for 32 x 256 GB DDR4 DIMMs1).

Free shipping on orders over $50!

  • Done Satisfaction Guaranteed
  • Done No Hassle Refunds
  • Done Secure Payments
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal

Description

Product overview

Related image, diagram or screenshot

The Cisco UCS C225 M6 SFF Rack Server extends the capabilities of the Cisco Unified Computing System portfolio in a 1-Rack-Unit (RU) form factor with the addition of AMD CPUs as well as 16 DIMM slots per CPU for 3200-MHz DDR4 DIMMs with individual DIMM capacity points up to 256 GB. The maximum memory capacity for two CPUs is 8 TB (for 32 x 256 GB DDR4 DIMMs1).

Features and benefits

There are several front drive and rear riser configurations, as listed below:

Front drives

●      Option 1: Up to 10 SAS/SATA/NVMe drives (up to 4 of the drives can be NVMe)

●      Option 2: Up to 10 NVME drives (All drives are NVMe)

Rear PCIe risers

●      One to three half-height PCIe risers, or

●      One to two full-height PCIe risers

The server provides an internal slot for one of the following:

●      Cisco 12G RAID controller with cache backup to control SAS/SATA drives, or

●      Cisco 12G SAS passthrough HBA to control SAS/SATA drives

Note:      NVMe drives are controlled directly from the CPUs.

The UCS C225 M6 server has a single 1 GbE management port. A modular LAN on motherboard (mLOM) / Open Compute Project (OCP) 3.0 module provides up to two 100 GbE ports. A connector on the front of the chassis provides KVM functionality.

The Cisco UCS C225 M6 server can be used either as a standalone or as part of the Cisco Unified Computing System, which unifies computing, networking, management, virtualization, and storage access into a single integrated architecture, enabling end-to-end server visibility, management, and control in both bare-metal and virtualized environments.

Product specifications

Table 1.        C225 M6 SFF specifications

Capability / featureDescription
ChassisOne Rack Unit (1RU) chassis
CPUOne or two AMD Milan or Rome processors
Memory32 slots for Registered DIMMs (RDIMMs) or Load-Reduced DIMMs (LRDIMMs)
Multi-bit error protectionThis server supports multi-bit error protection.
VideoThe Cisco Integrated Management Controller (CIMC) provides video using the Matrox G200e video/graphics controller:●  Integrated 2D graphics core with hardware acceleration●  Embedded DDR memory interface supports up to 512 MB of addressable memory (8 MB is allocated by default to video memory)●  Supports display resolutions up to 1920 x 1200 16 bpp @ 60 Hz●  High-speed, integrated 24-bit RAMDAC●  Single-lane PCI-Express host interface running at Gen 1 speed
Power subsystemUp to two of the following hot-swappable power supplies:●  1050 W (AC)●  1050 W (DC)●  1600 W (AC)●  2300 W (AC)One power supply is mandatory; one more can be added for 1 + 1 redundancy.
Front panelA front-panel controller provides status indications and control buttons.
ACPIThis server supports the Advanced Configuration and Power Interface (ACPI) 4.0 standard.
FansEight hot-swappable fans for front-to-rear cooling
InfiniBandThe InfiniBand architecture is supported by the PCIe slots.
Expansion slotsThree half-height riser slots●  Riser 1 (controlled by CPU 1):◦    One x16 PCIe Gen 4.0 slot (Cisco VIC), half-height, 3/4 length●  Riser 2 (controlled by CPU 1):◦    One x8 PCIe Gen 4.0 slot, half-height, 3/4 length●  Riser 3 (controlled by CPU 1):◦    One x16 PCIe Gen 4.0 slot (Cisco VIC), half-height, 3/4 lengthORTwo full-height riser slots●  Riser 1 (controlled by CPU 1):◦    One x16 PCIe Gen 4.0 slot (Cisco VIC), full-height, 3/4 length●  Riser 2 (controlled by CPU 1):◦    One x16 PCIe Gen 4.0 slot (Cisco VIC), full-height, 3/4 length
InterfacesRear panel:●  One 1Gbase-T RJ-45 management port●  One RS-232 serial port (RJ45 connector)●  One DB15 VGA connector●  Two USB 3.0 port connectors●  One flexible modular LAN on motherboard (mLOM)/OCP 3.0 slot that can accommodate various interface cardsFront panel:●  One KVM console connector (supplies two USB 2.0 connectors, one VGA DB15 video connector, and one serial port (RS232) RJ45 connector)
Internal storage devicesDrive storage:Drives are installed into front-panel drive bays, which provide hot-swappable access for SAS/SATA or NVMe drives. The server is orderable in two different versions:●  UCSC-C225-M6S (option 1):◦    Up to 10 SFF SAS/SATA Hard Drives (HDDs) or SAS/SATA Solid State Drives (SSDs)◦    Optionally, up to four SFF NVMe PCIe SSDs (replacing SAS/SATA drives). These drives must be placed in front drive bays 1, 2, 3, and 4 only and are controlled from CPU1. The rest of the bays (5 – 10) can be populated with SAS/SATA SSDs or HDDs.●  UCSC-C225-M6N (option 2):◦    Up to 10 SFF NVMe PCIe SSDs only. All drives are controlled from CPU1. Only one CPU is required when choosing NVMe SSDs.Other storage:●  A ministorage module connector on the motherboard supports a boot-optimized RAID controller carrier that holds two SATA M.2 SSDs. Mixing different capacity SATA M.2 SSDs is not supported.
Integrated management processorA Baseboard Management Controller (BMC) runs Cisco Integrated Management Controller (CIMC) firmware.Depending on your CIMC settings, the CIMC can be accessed through the 1-GE dedicated management port or a Cisco Virtual Interface Card (VIC).CIMC manages certain components within the server, such as the Cisco 12G SAS HBA.
Storage controllersOne Cisco M6 12G SAS RAID controller or up to two Cisco 12G SAS HBAs plug into a dedicated slot.Cisco M6 12G SAS RAID Controller with 4GB FBWC:●  RAID support (RAID 0, 1, 5, 6, 10, 50, 60, SRAID0, and JBOD mode)●  Supports up to 24 internal SAS/SATA drives●  Plugs into a dedicated slotCisco 12G SAS HBA:●  No RAID support●  JBOD/Pass-through Mode support●  Supports up to 16 SAS/SATA internal drives●  Plugs into a dedicated slot
Modular LAN on Motherboard (mLOM)/Open Compute Project (OCP) 3.0 slotThe dedicated mLOM/OCP 3.0 slot on the motherboard can flexibly accommodate the following cards:●  Cisco Virtual Interface Cards (VIC)●  OCP 3.0 network interface card (UCSC-O-ID10GC)
Cisco IntersightCisco Intersight provides server management capabilities.Note: Cisco UCS Manager (UCSM) support is not available for this server.
Cisco Integrated Management Controller (CIMC)Requires CIMC Release 4.2(1) or later
Operating temperatureMinimum 10°C to 35°C (50°F to 95°F) with no direct sunlight (If any A10, A100, or rear HDDs are installed, the 35°C (50°F) restriction changes to 30°C (86° F).)Maximum allowable operating temperature derated1C/300 m (1F/547 ft) above 950 m (3117 ft)
Extended operating temperature5°C to 40°C (41°F to 104°F) with no direct sunlightMaximum allowable operating temperature de-rated 1C/175 m (1F/319 ft) above 950 m (3117 ft)5°C to 4°5C (41°F to 113°F) with no direct sunlightMaximum allowable operating temperature de-rated 1C/125 m (1F/228 ft) above 950 m (3117 ft)System performance may be impacted when operating in the extended operating temperature range.Operation above 40°C is limited to less than 1% of annual operating hours.Hardware configuration limits apply to extended operating temperature range.
Nonoperating temperatureBelow -40°C or above 65°C (below -40°F or above 149°F)Maximum rate of change (operating and nonoperating)20°C/hr (36°F/hr)
Operating relative humidity8% to 90% and 24°C (75°F) maximum dew-point temperature, noncondensing environment
Nonoperating relative humidity5% to 95% and 33°C (91°F) maximum dew-point temperature, noncondensing environment
Operating altitude0 m to 3050 m {10,000 ft)
Nonoperating altitudeBelow 0 m or above 12,000 m (39,370 ft)

Reviews

There are no reviews yet.

Be the first to review “Cisco UCS C225 M6 SFF Rack Server”

Your email address will not be published. Required fields are marked *